Common PCR Errors and How to Avoid Them in Clinical Labs

Polymerase Chain Reaction (PCR) is the backbone of modern molecular diagnostics. It enables accurate detection of infectious agents, genetic mutations, and oncological markers in just a few hours.
However, despite its precision, PCR is highly sensitive to errors — even small mistakes can lead to false positives, false negatives, or inconsistent amplification.

At KeyBiotech, we emphasize not only providing high-quality PCR diagnostic kits but also educating laboratory professionals on best practices to ensure consistent, reliable results.


1. Contamination – The Most Common Enemy

Because PCR amplifies DNA exponentially, even trace amounts of contaminant DNA can lead to false-positive results.

Causes

  • Aerosolized amplicons from previous reactions
  • Cross-contamination between samples
  • Reagents or consumables exposed to nucleic acids

How to Avoid

✅ Use separate work zones for pre- and post-amplification processes.
✅ Always change gloves and pipette tips between samples.
✅ Employ filter (barrier) tips.
✅ Include negative controls in every run.
✅ Regularly clean benches and equipment with 10% bleach or UV decontamination.


2. Poor Sample Quality or Degraded Nucleic Acids

A successful PCR reaction starts with high-quality DNA or RNA. Impure or degraded nucleic acids can inhibit amplification or cause inconsistent results.

How to Avoid

  • Use validated nucleic acid extraction kits (KeyBiotech’s Extraction Series Kits are designed for this).
  • Avoid repeated freeze-thaw cycles.
  • Measure purity (A260/A280 ratio) before running PCR.
  • For RNA templates, store at −80 °C and use RNase-free consumables.

3. Inaccurate Primer Design

Primers are the “starting point” for amplification. Poorly designed primers can cause non-specific binding, primer-dimers, or failed amplification.

How to Avoid

  • Design primers using validated bioinformatics tools.
  • Check GC content (40–60%) and avoid long stretches of identical bases.
  • Verify primer specificity with a BLAST search.
  • Use KeyBiotech’s pre-validated primer sets for consistent performance.

4. Incorrect Annealing Temperature

Each primer pair has an optimal temperature at which it binds to the target DNA.
If the temperature is too low → non-specific binding.
If it’s too high → no amplification.

How to Avoid

  • Run a gradient PCR to determine the optimal annealing temperature.
  • Always verify the melting temperature (Tm) of both primers before setup.
  • Use a calibrated thermocycler and check temperature uniformity regularly.

5. Inhibitors in the Reaction Mix

Substances such as heme, ethanol, salts, or detergents can inhibit DNA polymerase activity, leading to false negatives.

How to Avoid

  • Ensure clean nucleic acid extraction.
  • Avoid over-loading the PCR with sample material.
  • Use inhibitor-resistant polymerases when working with challenging samples (e.g., stool, blood).

6. Pipetting and Volume Errors

Even small pipetting errors can disrupt PCR efficiency, especially in quantitative PCR (qPCR).

How to Avoid

  • Calibrate pipettes regularly.
  • Use consistent pipetting techniques and slow aspiration/dispense.
  • Prepare master mixes to minimize variability.
  • Avoid bubbles in reaction wells.

7. Thermal Cycler Calibration Issues

Temperature inconsistencies between wells can cause uneven amplification across the plate.

How to Avoid

  • Perform annual calibration and validation of your thermocycler.
  • Run temperature-verification tests using certified standards.
  • Use identical reaction volumes across all wells for uniform heating.

8. Misinterpretation of Results

In qPCR, misreading amplification curves or threshold settings can lead to incorrect conclusions.

How to Avoid

  • Use automatic threshold settings validated by your software.
  • Always compare with positive and negative controls.
  • Confirm unexpected results by re-testing the sample.
  • Maintain a recorded template for standard curve interpretation.

9. Lack of Routine Validation

Even with good technique, reagents can degrade or instruments can drift over time.

How to Avoid

  • Implement periodic performance checks.
  • Keep lot-to-lot validation data.
  • Use external quality assessment (EQA) or proficiency testing programs.

10. Ignoring Documentation and Traceability

Incomplete records make it difficult to identify where an error occurred.

How to Avoid

  • Maintain detailed PCR logs, including reagent lot numbers and operator IDs.
  • Use LIMS (Laboratory Information Management Systems) to track workflow.
  • Follow ISO 15189 and Good Laboratory Practice (GLP) standards.

KeyBiotech’s Quality Approach

At KeyBiotech, our molecular diagnostic kits are engineered to minimize error risks through:

  • Pre-validated primers and probes
  • Ready-to-use master mixes
  • Internal amplification controls
  • Comprehensive documentation and IFU guides

By combining high-quality reagents with proper laboratory practices, laboratories can ensure that each PCR run produces accurate and reproducible results.


Conclusion

PCR remains one of the most powerful tools in molecular diagnostics — but it demands precision, discipline, and awareness.
By understanding common errors and adopting rigorous quality control practices, clinical labs can safeguard against false results and maintain diagnostic excellence.

At KeyBiotech, we continue to support laboratories worldwide with advanced PCR kits and expert guidance that deliver reliability at every step of testing.

Shopping Cart